翻訳と辞書
Words near each other
・ Dossinia
・ Dosso
・ Dosso Airport
・ Dosso del Liro
・ Dosso Department
・ Dosso Dossi
・ Dosso Kingdom
・ Dosso Region
・ Dosso Reserve
・ Dosso, Niger
・ Dossobuono
・ Dossor
・ Dose-dense chemotherapy
・ Dose-fractionation theorem
・ Dose-ranging study
Dose-volume histogram
・ Dosed
・ Dosehra
・ Doseido Colony, Texas
・ Doselle Young
・ DOSEMU
・ Dosenbek
・ Doseon
・ Doseon-dong
・ Doseone
・ Doseonsa
・ Dosetai
・ Dosewallips River
・ Dosewallips State Park
・ Dose–response relationship


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Dose-volume histogram : ウィキペディア英語版
Dose-volume histogram

A dose-volume histogram (DVH) is a histogram relating radiation dose to tissue volume in radiation therapy planning. DVHs were introduced by Michael Goitein (who introduced radiation therapy concepts such as the "beam's-eye-view," "digitally reconstructed radiograph," and uncertainty/error in planning and positioning, among others) and Verhey in 1979 in a publication by Shipley et al. DVH summarizes 3D dose distributions in a graphical 2D format. In modern radiation therapy, 3D dose distributions are typically created in a computerized TPS (Treatment Planning System) based on a 3D reconstruction of a CT scan. The "volume" referred to in DVH analysis is a target of radiation treatment, a healthy organ nearby a target, or an arbitrary structure.
DVHs can be visualized in either of two ways: differential DVHs or cumulative DVHs. A DVH is created by first determining the size of the dose bins of the histogram. Bins can be of arbitrary size, e.g. 0-1 Gy, 1.001-2 Gy, 2.001-3 Gy, etc.
In a differential DVH, bar or column height indicates the volume of structure receiving a dose given by the bin. Bin doses are along the horizontal axis, and structure volumes (either percent or absolute volumes) are on the vertical. The differential DVH takes the appearance of a typical histogram.
The cumulative DVH is plotted with bin doses along the horizontal axis, as well. However, the column height of the first bin (0-1 Gy, e.g.) represents the volume of structure receiving greater than or equal to that dose. The column height of the second bin (1.001-2 Gy, e.g.) represents the volume of structure receiving greater than or equal to that dose, etc. With very fine (small) bin sizes, the cumulative DVH takes on the appearance of a smooth line graph. The lines always slope and start from top-left to bottom-right. For a structure receiving a very homogenous dose (100% of the volume receiving exactly 10 Gy, for example) the cumulative DVH will appear as a horizontal line at the top of the graph, at 100% volume as plotted vertically, with a vertical drop at 10 Gy on the horizontal axis. A DVH used clinically usually includes all structures and targets of interest in the radiotherapy plan, each line plotted a different color, representing a different structure. The vertical axis is almost always plotted as percent volume (rather than absolute volume), as well.
Clinical studies have shown that DVH metrics correlate with patient toxicity outcomes. A drawback of the DVH methodology is that it offers no spatial information; i.e., a DVH does not show where within a structure a dose is received. Also, DVHs from initial radiotherapy plans represent the doses to structures at the start of radiation treatment. As treatment progresses and time elapses, if there are changes (i.e. if patients lose weight, if tumors shrink, if organs change shape, etc.), the original DVH loses its accuracy.
==References==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Dose-volume histogram」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.